De Aller-Bedste Bøger - over 12 mio. danske og engelske bøger
Levering: 1 - 2 hverdage

Performance enhancement of Thermal Radiant Cooling System

Performance enhancement of Thermal Radiant Cooling Systemaf Rahul Goyal
Bag om Performance enhancement of Thermal Radiant Cooling System

This book contains the successful experiment on the application of radiant cooling using natural air for ventilation under the hot and humid climate of Rajasthan was studied. To avoid condensation of moisture on the cooling panel, the temperature of water supplied to the panel was limited to dew point temperature. Experiments were conducted in an experimental cabin during the hot and dry period in the month of March 2016. Results confirmed the good potential for application of radiant cooling. However, the room was served by radiant panels with a total area of (6 ×4) square feet. A special configuration was devised to achieve thermal comfort for the area served by the panel. ###Key Features- Figures and Graphs for better understanding.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9786200277220
  • Indbinding:
  • Paperback
  • Sideantal:
  • 100
  • Udgivet:
  • 8. august 2019
  • Størrelse:
  • 150x6x220 mm.
  • Vægt:
  • 167 g.
  • 2-3 uger.
  • 12. december 2024
På lager

Normalpris

Abonnementspris

- Rabat på køb af fysiske bøger
- 1 valgfrit digitalt ugeblad
- 20 timers lytning og læsning
- Adgang til 70.000+ titler
- Ingen binding

Abonnementet koster 75 kr./md.
Ingen binding og kan opsiges når som helst.

Beskrivelse af Performance enhancement of Thermal Radiant Cooling System

This book contains the successful experiment on the application of radiant cooling using natural air for ventilation under the hot and humid climate of Rajasthan was studied. To avoid condensation of moisture on the cooling panel, the temperature of water supplied to the panel was limited to dew point temperature. Experiments were conducted in an experimental cabin during the hot and dry period in the month of March 2016. Results confirmed the good potential for application of radiant cooling. However, the room was served by radiant panels with a total area of (6 ×4) square feet. A special configuration was devised to achieve thermal comfort for the area served by the panel. ###Key Features- Figures and Graphs for better understanding.

Brugerbedømmelser af Performance enhancement of Thermal Radiant Cooling System



Find lignende bøger
Bogen Performance enhancement of Thermal Radiant Cooling System findes i følgende kategorier: