De Aller-Bedste Bøger - over 12 mio. danske og engelske bøger
Levering: 1 - 2 hverdage

Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Highly Stretchable Microflow Sensor for Monitoring of Hemodynamicsaf Woon-Hong Yeo
Bag om Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Random weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that a flow-diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion. Therefore, physicians rely heavily on either angiography or magnetic resonance imaging, which require a dedicated facility with sophisticated equipment and time-consuming procedures. Here, this work introduces an implantable, stretchable, nanostructured flow-sensor system for quantification of intra-aneurysmal hemodynamics. The open-mesh membrane device is capable of effective implantation in complex neurovascular vessels with extreme stretchability (500% radial stretching) and bendability (180 degrees) for monitoring of the treatment progress. In vitro demonstrations of three types of flow-sensors show quantification of intra-aneurysmal blood flow in a pig aorta and the capability of observation of aneurysm treatment with a great sensitivity (detection limit: 0.032 m/s).

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9786139924608
  • Indbinding:
  • Paperback
  • Sideantal:
  • 52
  • Udgivet:
  • 10. oktober 2018
  • Størrelse:
  • 150x4x220 mm.
  • Vægt:
  • 96 g.
  • 2-3 uger.
  • 11. december 2024
På lager

Normalpris

Abonnementspris

- Rabat på køb af fysiske bøger
- 1 valgfrit digitalt ugeblad
- 20 timers lytning og læsning
- Adgang til 70.000+ titler
- Ingen binding

Abonnementet koster 75 kr./md.
Ingen binding og kan opsiges når som helst.

Beskrivelse af Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Random weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that a flow-diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion. Therefore, physicians rely heavily on either angiography or magnetic resonance imaging, which require a dedicated facility with sophisticated equipment and time-consuming procedures. Here, this work introduces an implantable, stretchable, nanostructured flow-sensor system for quantification of intra-aneurysmal hemodynamics. The open-mesh membrane device is capable of effective implantation in complex neurovascular vessels with extreme stretchability (500% radial stretching) and bendability (180 degrees) for monitoring of the treatment progress. In vitro demonstrations of three types of flow-sensors show quantification of intra-aneurysmal blood flow in a pig aorta and the capability of observation of aneurysm treatment with a great sensitivity (detection limit: 0.032 m/s).

Brugerbedømmelser af Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics



Find lignende bøger
Bogen Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics findes i følgende kategorier: