De Aller-Bedste Bøger - over 12 mio. danske og engelske bøger
Levering: 1 - 2 hverdage

Improvement of Heat Transfer in Solar Air Heater

Improvement of Heat Transfer in Solar Air Heateraf Gurpreet Singh
Bag om Improvement of Heat Transfer in Solar Air Heater

The concept of V-shaped rib was developed to capitalize on this span-wise variation of heat transfer for inclined ribs. The V-shaped rib reduced span-wise variation of heat transfer and increased average heat transfer. The heat transfer results have been compared with those for smooth ducts under similar flow and thermal boundary conditions. It is found that the angled ribs give higher heat transfer rate than transverse ribs, because of the secondary flow induced by the rib angle, in addition to breaking the laminar sub-layer and producing local wall turbulence. The results show that the V-shaped down rib with gap performs better than the angled ribs because of the development of two vortices cells compared to only one cell in the case of inclined ribs.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9786206740186
  • Indbinding:
  • Paperback
  • Sideantal:
  • 112
  • Udgivet:
  • 12. juli 2023
  • Størrelse:
  • 150x7x220 mm.
  • Vægt:
  • 185 g.
  • 2-3 uger.
  • 14. december 2024
På lager
Forlænget returret til d. 31. januar 2025

Normalpris

Abonnementspris

- Rabat på køb af fysiske bøger
- 1 valgfrit digitalt ugeblad
- 20 timers lytning og læsning
- Adgang til 70.000+ titler
- Ingen binding

Abonnementet koster 75 kr./md.
Ingen binding og kan opsiges når som helst.

Beskrivelse af Improvement of Heat Transfer in Solar Air Heater

The concept of V-shaped rib was developed to capitalize on this span-wise variation of heat transfer for inclined ribs. The V-shaped rib reduced span-wise variation of heat transfer and increased average heat transfer. The heat transfer results have been compared with those for smooth ducts under similar flow and thermal boundary conditions. It is found that the angled ribs give higher heat transfer rate than transverse ribs, because of the secondary flow induced by the rib angle, in addition to breaking the laminar sub-layer and producing local wall turbulence. The results show that the V-shaped down rib with gap performs better than the angled ribs because of the development of two vortices cells compared to only one cell in the case of inclined ribs.

Brugerbedømmelser af Improvement of Heat Transfer in Solar Air Heater



Find lignende bøger
Bogen Improvement of Heat Transfer in Solar Air Heater findes i følgende kategorier: